Guaranteed safety of industrial facilities

The Platform RadICS B is robust, flexible, and scalable. It delivers state-of-the-art functions, services, and safeguards for applications industrial. The Platform RadICS B components are designed to the latest IEC standards for nonsafety service in industrial systems. The Platform RadICS B consists of a Logic Module, basic input/output modules, and specialty modules all housed in a seismically qualified chassis.

Guaranteed safety of industrial facilities

The Platform RadICS B is robust, flexible, and scalable. It delivers state-of-the-art functions, services, and safeguards for applications industrial. The Platform RadICS B components are designed to the latest IEC standards for nonsafety service in industrial systems. The Platform RadICS B consists of a Logic Module, basic input/output modules, and specialty modules all housed in a seismically qualified chassis.

Logic Module (LM)

Radiy delivers a digital I&C platform that is robust, flexible, and scalable. It provides state-of-the-art functions, services, and safeguards for applications in industry. The RadICS B product line consists of a Logic Module, basic input/output modules, and specialty modules all housed in a chassis. The Logic Module serves as the brain for the entire platform. In addition to executing the application logics, the Logic Module communicates with all other modules installed in the chassis, performs and monitors self-diagnostics, and controls communications with external chassis and systems.

Analog Inputs Module (AIM)

Radiy delivers a digital I&C platform that is robust, flexible, and scalable. It provides state-of-the-art functions, services, and safeguards for applications in industry. The RadICS B product line consists of a Logic Module, basic input/output modules, and specialty modules all housed in a chassis. The Analog Inputs Module (AIM) serves as a high-density analog field sensor acquisition module. It provides for 32 independent, highly reliable, and galvanically isolated inputs with built- in filtering and calibration to be used by the Logic Module. The AIM also performs robust and continuous self-diagnostics to ensure the safety and integrity of each output and module function.

Analog Outputs Module (AOM)

Radiy delivers a digital I&C platform that is robust, flexible, and scalable. It provides state-of-the-art functions, services, and safeguards for applications in industry. The RadICS B product line consists of a Logic Module, basic input/output modules, and specialty modules all housed in a chassis. The Analog Outputs Module (AOM) serves as a high-density output conditioning module providing for 32 independent, highly reliable, and galvanically isolated analog outputs. The Logic Module uses the AOM to drive field devices, indicators, and other functions. The AOM also performs robust and continuous self-diagnostics to ensure the safety and integrity of each output and module function.

Discrete Inputs Module (DIM)

Radiy delivers a digital I&C platform that is robust, flexible, and scalable. It provides state-of-the-art functions, services, and safeguards for applications in industry. The RadICS B product line consists of a Logic Module, basic input/output modules, and specialty modules all housed in a chassis. The Discrete Inputs Module (DIM) serves as a high-density discrete dry contact module providing for 64 independent inputs for use by the Logic Module. The DIM also performs robust and continuous self-diagnostics to ensure the safety and integrity of each input and module function.

Discrete Outputs Module (DOM)

Radiy delivers a digital I&C platform that is robust, flexible, and scalable. It provides state-of-the-art functions, services, and safeguards for applications in industry. The RadICS B product line consists of a Logic Module, basic input/output modules, and specialty modules all housed in a chassis. The Discrete Outputs Module (DOM) serves as a high-density module providing for 32 independent, highly reliable, and galvanic isolated discrete outputs. The Logic Module uses the DOM to drive field devices, indicators, and other functions. The DOM also performs robust and continuous self-diagnostics to ensure the safety and integrity of each output and module function.

Optical Communication Module (OCM)

Radiy delivers a digital I&C platform that is robust, flexible, and scalable. It provides state-of-the-art functions, services, and safeguards for applications in industry. The RadICS B product line consists of a Logic Module, basic input/output modules, and specialty modules all housed in a chassis. The Optical Communication Module (OCM) receives and transmits data via up to five independent safety qualified point to point fiber optic interfaces that are used to extend the RadICS Platform to additional chassis (OCM to OCM or OCM to LM). The OCM also performs robust and continuous self-diagnostics to ensure the safety and integrity of data transfer and module function.

Resistance Input Module (RIM)

Radiy delivers a digital I&C platform that is robust, flexible, and scalable. It provides state-of-the-art functions, services, and safeguards for applications in industry. The RadICS B product line consists of a Logic Module, basic input/output modules, and specialty modules all housed in a chassis. The Resistance Input Module (RIM) serves as a high-density resistance sensor acquisition module. It provides for 16 independent, highly reliable, and galvanically isolated inputs with built-in filtering and calibration to be used by the Logic Module. The RIM also performs robust and continuous self-diagnostics to ensure the safety and integrity of each input and module function.

Thermocouple Input Module (TIM)

Radiy delivers a digital I&C platform that is robust, flexible, and scalable. It provides state-of-the-art functions, services, and safeguards for applications in industry. The RadICS B product line consists of a Logic Module, basic input/output modules, and specialty modules all housed in a chassis. The Thermocouple Input Module (TIM) serves as a high-density thermocouple sensor acquisition module. It provides for 32 independent, highly reliable, and galvanically isolated inputs with built-in filtering and calibration to be used by the Logic Module. The TIM also performs robust and continuous self-diagnostics to ensure the safety and integrity of each input and module function.